Brand Name : MINGYANG
Model Number : MY-3200
Place of Origin : China Mainland
MOQ : 1
Price : 2000-2500usd
Payment Terms : L/C,D/A,D/P,T/T,Western Union
Supply Ability : 1000pcs/month
Delivery Time : 1 week
Packaging Details : carton
Type : Testing Machine
Protection Class : IP65
Customized support : OBM, ODM, OEM
Warranty : 2 Year
Power consumption of the whole machine : 30W (static) and 150W (working)
PT error accuracy : 0.05 level
Environmental temperature : 0-40℃
Place of origin : Hubei, China
Environmental humidity : <85% at 25℃
Voltage : 220V
Power : 1200KV
Application : Electrical Testing
Accuracy : 0.2%
Rated Output Power : 2000W
Peak Output Power : 3000W
AC Output : 220V (±10% rms), 50/60Hz switchable
DC Output Ports : 5V/3.1A, 12V/20A, 24V/10A, 48V/50A
Efficiency : > 87%
Built-in Battery Capacity : 50Ah / 48V
Protection Features : Overload, low voltage warning, overvoltage protection with auto shutdown
Cooling : Variable-speed fan (requires ventilation)
Operating Environment : 0-40℃, 0-95% RH (non-condensing)
Noise Level : < 60dB
This 2000W emergency power supply features an LCD display, multiple voltage DC outputs, and comprehensive protection systems including overload and low voltage protection for reliable power backup solutions.
| Parameter | Specification |
|---|---|
| AC Output Voltage | AC 220V (±10% rms) |
| AC Output Frequency | 50/60Hz ± 0.3Hz |
| Efficiency | > 87% |
| DC Output Voltage / Current | DC 5V/3.1A, DC 12V/20A, DC 24V/10A, DC 48V(±8V)/50A |
| Rated Output Power | 2000W |
| Peak Output Power | 3000W |
| Overload Protection (SMPS load) | (110% < Load < 125%) ±10%: Output voltage cuts off after 15 minutes (125% < Load < 150%) ±10%: Output voltage cuts off after 10 seconds Load > 150% ±10%: Output voltage cuts off after 0.2 seconds |
| Low Voltage Warning | 42.0Vdc ± 1.2Vdc (for 48V power supply) |
| Low Voltage Auto Shutdown | 40.0Vdc ± 1.2Vdc (for 48V power supply) |
| Input Over-voltage Warning & Shutdown | 64Vdc ± 1.2Vdc (for 48V power supply) |
| Input Over-voltage Recovery | 62.0Vdc ± 1.2Vdc (for 48V power supply) |
| Cooling | Variable-speed fan, use in well-ventilated conditions |
| Operating Environment & Noise | Temperature & Humidity: 0-40℃, 0-95% RH (non-condensing) Noise: < 60dB |
| Built-in Battery Capacity | 50Ah / 48V |
|
|